Sony Petasite Library

Certified Device Drivers

Installation of the following certified device driver combination is described below.

Device Driver Manufacturer
LTO drive(s) IBM
Medium Changer XenData

Device Driver Installation for XenData Server Software

Installation Prerequisites  XenData Hardware

Ensure that the tape hardware is connected to the server. For SAS connections you must have point to point connections, for Fibre channel you can connect via a switch, however our recommendation is also point to point. The tape hardware must be powered on and in a ready state.

Tape Drive Drivers  XenData Hardware

The server operating system may install Microsoft device drivers for any attached IBM tape drives and will install a XenData driver for the tape library's medium changer. The tape drive drivers should be changed as described here.

Download the zipped device driver installation files from the link below to a folder on the C: drive of the Server.

» Download device driver - Windows 2008 R2

» Download device driver - Windows 2012 R2

Unzip the files. Browse to the 'install_exclusive.exe' file and right-click on it. Select 'Run as administrator'. The program will launch a command line window and then display 'Program Successful'.

This completes the installation of an IBM device driver.

Note that if connections to the SAS or Fibre ports on the rear of the server are swapped, it may be necessary to reinstall the driver.

Library Drivers  XenData Hardware

Windows Server 2008 R2 and Server 2012 R2 use digitally signed drivers, so the XenData library driver will be automatically used when the hardware is attached.

Supported Tape Formats  XenData Hardware

The following drive/media combinations are supported by the software with IBM LTO-4, LTO-5 and LTO-6 drives:

  Media                
Drive Ultrium 2 R/W Ultrium 3 R/W Ultrium 3 WORM Ultrium 4 R/W Ultrium 4 WORM Ultrium 5 R/W Ultrium 5 WORM Ultrium 6 R/W Ultrium 6 WORM
  200 GB 400 GB 400 GB 800 GB 800 GB 1500 GB 1500 GB 2500 GB 2500 GB
LTO-4 X X X X X
LTO-5 X read only read only X X
LTO-6 X X X read only read only